F75 Fault on Vaillant Boiler – Easy Fix Guide 2025

Vaillant boiler showing F75 fault code on display screen

Table of Contents

The F75 defects on a Vaillant boiler occur when the system fails to detect pressure changes during the start -up. This is usually caused by a deficient pressure sensor or a failed pump. When this error appears, the boiler may stop working, which can leave you without hot or hot water.

In this guide, we will explain what is the cause of the F75 error and how to fix it. We will also discuss that you may need to change the parts and when to call a professional.

What Causes the Vaillant Boiler F75 Error?

The F75 defects are triggered when the boiler system does not detect pressure change. There are two most common reasons for this:

  1. Furious pressure sensor: The sensor is responsible for detecting pressure changes. If this is a malfunction, the boiler cannot identify the correct pressure, causing the F75 error.
  2. FAIL Pump: The pump transfers water through the heating system. If it is weak or blocked, the pressure will not increase as expected, which will make a mistake.
 

Other possible causes include:

  • Low water pressure in the system
  • Blocked or dirty pipes
  • Air trapped in the radiators
  • A leak in the system
 

Now, let’s go through the steps to diagnose and fix the issue.

How to Troubleshoot and Fix F75 Fault on a Vaillant Boiler?

1. Check the Boiler’s System Pressure

First look at the pressure gauge on the boiler. The normal pressure should be between 1.0 and 1.5 times when the system is cooled. If the pressure is very low, it can cause F75 errors.

  • If the pressure is below 1.0 bar, it means the system needs more water.
  • If the pressure is above 2.5 bar, it may indicate an over-pressurization issue.
 

To increase the pressure:

  1. Locate the filling loop (usually a silver or black flexible hose with two valves).
  2. Open both valves slowly to allow water into the system.
  3. Watch the pressure gauge and stop when it reaches 1.2 – 1.5 bar.
  4. Close both valves and restart the boiler.
 

If the pressure is low, the system may have a leak that requires fixing.

2. Bleed the Radiators

Air trapped in the system can cause pressure issues. Bleeding the radiators helps remove trapped air and allows the system to function properly.

  1. Turn off the heating system.
  2. Use a radiator key to open the bleed valve on each radiator.
  3. Let the air escape until the water begins to get out.
  4. Close the valve and check the boiler pressure again.
  5. If the pressure has dropped, top it up using the filling loop.

3. Reset the Boiler

Sometimes, a simple reset can clear the F75 error.

  1. Locate the reset button on the boiler’s control panel.
  2. Press and hold the button for a few seconds.
  3. Wait for the boiler to restart.
  4. Check if the F75 fault code disappears.
 

If the error comes back, further troubleshooting is needed.

4. Check the Pump

A failing pump is a common cause of the F75 fault. The pump cannot create enough pressure for the boiler to detect a change.

  • Listen to a lukewarm sound when the boiler starts. If quiet, the pump cannot work.
  • Try to drain the pump gently to see if it starts to go.
  • If the pump is leaking or making noise high, it can be blocked or failed.
 

In some cases, the pump may need to be cleaned or replaced.

5. Replace the Pressure Sensor (If Necessary)

The pressure sensor is responsible for detecting pressure changes. If dirty or broken, it does not send the correct signal to the boiler.

Signs of a faulty pressure sensor:

  • The boiler pressure is correct, but the F75 error persists.
  • The error appears randomly, even when the pump is working.
 

A heating engineer can replace the Vaillant F75 pressure sensor if it is faulty.

When to Call a Professional?

If you have tried the above steps and the F75 fault still appears, it’s time to call a Gas Safe engineer. A professional can:

  • Check for hidden leaks in the system.
  • Clean or replace the pump if it is failing.
  • Install a new pressure sensor if necessary.
  • Inspect the boiler’s internal components for further issues.
 

Attempting to replace parts yourself can be risky if you are not trained. A professional will ensure everything is fixed safely and correctly.

Preventive Maintenance Tips to Avoid Future F75 Faults

To prevent the F75 error from happening again, follow these maintenance tips:

  • Check boiler pressure regularly. Make sure it stays between 1.0 – 1.5 bar.
  • Bleed radiators every few months to remove trapped air.
  • Book an annual boiler service to inspect and clean internal parts.
  • Use a magnetic filter to prevent debris from blocking the system.
  • Keep the heating system clean by using a system flush every few years.
 

Regular renovation can help your Vaillant boiler run efficiently and decrease the probability of breakdowns.

Conclusion

The F75 defects on a valent boiler occur when the system fails to detect pressure changes. This is usually caused by a deficient pressure sensor or a failed pump. Pressure, bleeding and boiler reset on the boiler can sometimes solve the problem.

If the problem persists, a gassy engineer may need to replace the pressure sensor or pump. Regular boiler upkeep can assist prevent future F75 defects, which run your heating system. If you are eligible, the Eco4 Scheme may help cover the cost of necessary upgrades or replacements.

If you are uncertain of any step, it’s miles constantly high-quality to are seeking professional assist. By solving the hassle speedy, you could store cash and ensure your home is warm and snug.

FAQs

How do I clear my Vaillant fault code?

If you’ve got a fault code showing on your Vaillant boiler, the first thing to try is a reset. Most models have a reset button right on the front. Press it and hold for a few seconds. In many cases, that’s enough to get things working again. But if the error keeps popping up, that’s usually a sign something’s wrong like low pressure, or a part that’s not working properly. At that point, it’s best to call out a heating engineer.

What does the F75 fault mean on the pump?

The F75 error typically means the boiler isn’t picking up a pressure change when the pump switches on. That can happen for a few reasons. Sometimes the pump’s stuck. Other times, the pressure sensor might be dirty or faulty. If you’re seeing this fault regularly, it’s worth having a professional take a look to see what’s causing it.

What should I do if my Vaillant boiler has low pressure?

Low pressure is pretty common and usually easy to sort out. Take a look at the pressure gauge if it’s below 1 bar, you’ll need to add water using the filling loop (that’s usually a small silver hose under the boiler). Open the valves slowly and let the pressure rise to about 1.5 bar. Then close them up again. If the pressure keeps dropping over time, you might have a leak somewhere in the system.

What does the F75 fault mean on a Heatline boiler?

Just like with Vaillant, the F75 fault on a Heatline boiler points to a problem with water pressure detection. The boiler’s trying to start the pump, but it doesn’t see any pressure change. It could be a faulty sensor, an issue with the pump, or the system might just be low on pressure. Either way, it usually needs a proper check from a qualified engineer.